Experimental Techniques at the Institute for Solid State Research
The IFF applies various sophisticated experimental methods in order to study the following properties:
3. Acoustic/elastic properties
1. Methods to study magnetic properties
-
Quantum Design SQUID Magnetometer (5T, 1.5-400K, Oven (-800K), Rotator, Ultra-Low-field option, Hydrostatic Pressure Cell up to 1GPa)
- Vibrating Sample Magnetometer (17T, 2.5-300K)
-
Quantum Design PPMS (9T, 0.5-350K; Specific heat, AC-susceptibility, Torque-Magnetometer, Electrical+heat transport)
- Magnetostriction, Thermal Expansion (18T, 2-300K)
- Pulsed Field Magnetometer (60 T)
- Alternating gradient magnetometer (1T, 10-470K)
- Breit-Band-ESR-Spektrometer auf Basis von Millimeterwave Vector Network Analyzator (16GHz-1THz, bis 17T, 0.3-300K)
- Breit-Band-ESR-Spektrometer auf Basis von Millimeterwave Backward Oscillators (180GHz -1THz, bis 17T (mit optischen Fenstern bis 11T), 1.8 - 300K)
- Bruker X-Band ESR Spektrometer (9,5GHz, bis 1T, 4 - 300K)
- 4 NMR/NQR Spektrometer ( 3 Kernspinresonanzspektrometer (Tecmag Apollo), 6 - 500MHz, ein Spektrometer (Magma) für tiefe Frequenzen, 0.2 - 50MHz, ein 7T Magnet, ein 9,2T Magnet mit variablem Feld, 2 - 500K
2. Methods to study electronic properties
- Photoelektronenspektrometer für Valenzband- und Rumpfniveauphotoemission (UPS/XPS)
- Photoelektronenspektrometer für Valenzbandphotoemission (ARPES)
- Elektronen-Energieverlustspektroskopie in Transmission (EELS)
- Elektronen-Energieverlustspektroskopie in Reflexion (HREELS)
- Röntgenabsorptionsspektroskopie (XAS/NEXAFS)
- Fourier-Rahmenspektrometer
- IR/UV-vis Spektrometer
- Transporteigenschaften (elektr. Widerstand, Hall-Effekt, Wärmeleitfähigkeit, Thermokraft, Nernst-Effekt, Righi-Leduc-Effekt, Ettinghausen-Effekt)
(16T, 2-300K, Ausbau bis 300mK geplant) - STN/STS (VT-STM (Omicron), 9T-300mK-UHV-STM im Aufbau (mit Spinpolarisation), 4K-Dipstick im Aufbau)
- Transporteigenschaften von Nanostrukturen (Mischungskryostat (10T, 25mK-300K), elektrischer Widerstand, Tunnelmagnetowiderstand)
- Netzwerkanalysatoren (300kHz - 3GHz)
-
2.1 Redox Properties
- Spectroelectrochemical Methods to study charge transfer reactions:
- in situ ESR-UV/Vis/NIR spectroelectrochemistry
- in situ UV/Vis/NIR spectroelectrochemistry
- in situ Raman spectroelectrochemistry
- in situ FTIR spectroelectrochemistry
- in situ NMR spectroelectrochemistry
- in situ AFM/STM electrochemistry
- Thermoelectrochemistry
3. Methods to study acoustic/elastic properties
-
Laser-induced SAW Pulse Technique (-10 ... +80°C, working frequency up to 400 MHz)
- SAW Probe (lateral resolution down to 25 nm, working frequency up to 200 MHz)
- Acoustic Wave Computing
- Brillouin Spectroscopy
- Ultrasonic Pulse-Echo Measurement System (frequency 0.25 ... 40 MHz, 4.2 ... 380 K, sound velocity (phase angle) 0.03 degrees)
4. Methods to study dielectric properties
- Pyroelectric Microscope
- Polarisation Loop Tracer (up to 10000 V, 4.2 ... 600 K, input amplifier 1 pA ... 1 A)
-
Wideband Dielectric Spectrometer (frequency 1 ... 32 MHz, 4.2 ... 600 K, dielectric constant)
5. Structure
- Elektronenmikroskop XL30 Philipps, IN400 ( SEM, WDX, EDX)
- Elektronenmikroskop Nanosem ( SEM, STEM, low vacuum, EDX, Auflösung bis max. 400 000x)
- DME-Rasterscope, AFM ( an Luft, AC-Mode, DC-Mode)
- Mikrohärteprüfgerät (Vickers-Mikrohärte, konventionell)
6. Crystal growth facilities
- Electromagnetic levitation technique (EML) for melt undercooling experiments (245 kHz)
- Gloveboxen für inertes Arbeiten
- Lichtbogenofen zur Materialpräparation
- Öfen für Wärmebehandlungen unter definierten Atmosphären bis 1700°C
- Vertical Bridgman technique crystal growth apparature Granat-400 ( 2250°C)
- Induktions-Schmelzanlage 15 kW/600 kHz
- Induktions-Zonenschmelzanlagen für 30 kW/250 kHz bzw. 10 kW/3 MHz
- 2 Zonenschmelzanlagen mit Strahlungsheizung (MEI Moskau (Russland), CSI Japan)
- SFZ Zonenschmelzanlage mit Strahlungsheizung (Hochdruck bis 150 bar, Eigenentwicklung im IFW)
- Induktions-Kalttiegel-Kristallzüchtungsanlage für Probenpräparation bis 30 g
- Thermoanalyse mit DTA/TG und Hochtemperatur DTA bis 2400°C