| Typ | FASTCAM SA3 |
| Max. frame rate | 120,000 fps at 128 x 16 pixels |
| Standard frame rate | 2000 fps at 1024 x 1024 resolution |

| Measurement equipment for classification of laboratories |
| Very high sensitive acceleration sensors (1000 mV/g) |
| Real-time data acquisition, long term recording and data management |
| Integrated post-processing and reporting |
| CPB (Constant Percentage Bandwidth) is a standardized digital filter-based analysis using 1/1, 1/3, 1/12 and 1/24 octaves |

| Measurements of electro-magnetic emission and immission |
| Implementation of methods for radio frequency attenuation and damping |
| EMC measurements for health and safety at the workplace |
| Analyzing of conductive and radiation coupling from 9 kHz to 8 GHz |
| Recommendations for EMC design |

| Exposure to human body regulated in standard EN50499 |
| Measurement tools for occupational and public exposure against reference levels available |
| General purpose measurements of 100nT to 100mT with true RMS AC/DC |
| Possibilities to select frequency range from DC – 400 kHz |
| Automatic data logging includes spectrum analysis with FFT |
| Hand held Tesla-Meter up to 2.5 T available |

| Acoustic power from pumps, air conditioners or ambient noise |
| Qualification of rooms with sound power measurements |
| Test of components with low sound power ratings |
| Spectrum analysis using FFT and digital filters |
| No detectable influence from magnetic field at 80 A/m, 50 Hz |
| Low noise floor of typically 5.5 dbA |
| Frequency range 10 – 16000 Hz includes parts of infrasound |

| Measuring depth | +/- 50 mm |
| Average working distance | 150 mm |
| Measuring distance (measuring object to the camera) | 2.0 to 4.0m |
| Measuring volume | 6,3 m³ |

| Precise video measurement | Motorized 5: 1 AccuCentric zoom lens, calibrates automatically after every change of the zoom position |
| Process movement (X,Y,Z) | 250 x 150 x 150 mm |
| Image field size | Measured diagonally from 5.0 mm (low magnification) to 0.9 mm (high magnification) |

| Workspace (diameter) | 0.6 - 1.2m |
| Accuracy specification | F04-02 MPE (µm) 5 + 8L / 1000 |
| Measurement accuracy | 0.018mm |